Vapor Recovery
External Vapor Condensers | Specifications | DXC Conversion Unit

External Vapor Condenser - KRVC-II and KRVC-III

KVCR III CondenserKVCR II Condenser

Kleen-Rite Vapor Condensers Plant-Tested by the U.S.E.P.A.
Why risk the uncertainty of wondering whether you're in compliance with EPA regulations? Kleen-Rite Vapor Condensers have been U.S.E.P.A. tested 95% efficient and that means less perc in the environment and in your plant.

New Clean Air Act Requires Perc Vapor Control
Kleen-Rite Vapor Condensers can be easily adapted for compliance. Once installed, that's automatic efficiency you can count on.

Occupies Less Space
Kleen-Rite Vapor Condensers take up less room than carbon absorbers. They're even available in ceiling mount units -- an added bonus considering you often need all the floor space you can get.

Service Once A Month Vs. Everyday
With Kleen-Rite Vapor Condensers, there's no daily maintenance involved. All you have to do is change the condenser air filter on a monthly basis and even that can be done while you're cleaning. So check out Kleen-Rite's complete line of industrial-size vapor condensers. They'll increase your profits and you peace of mind.

To Page Top

KRVC-II & KRVC-III Specifications

Dry to Dry System
Floor Series KRVC - II KRVC - II Transfer KRVC - III KRVC - III Transfer
Sized for: Dry To Dry Only One Unit Up to 60# N/A One Unit Up to 120# N/A
Sized for: Transfer System N/A One - 60# Dryer With One - 60# Washer N/A One - 60# to #120 Dryer With One - 60# to #120 Washer
Number of Evaporator Tanks One Two One Two
Dryer Evap Tank - Port Dia. 4" 4" 4" 4"
Transfer Evap Tank - Port Dia. N/A 6" N/A 4"

 

Refrigeration KRVC - II KRVC - III KRVC - II
KRVC II Dimensions Diagram

KVRC - III
KRVC III Dimensions Diagram

Type of Refrigerant R-22 R-22
Lbs. of Refrigerant 6 Lbs. 12.5 Lbs.
Expansion Valve - Std Tank BFVE-AE BFVE-BC
Expansion Valve - Tra Tank GR - 1/2C GR - 1/2C
Suction Accumulator KR-P/N 000525 KR-P/N 000525
Sight Glass KR-P/N 000153 KR-P/N 000153
Pressure Control - Cut In 60 60
Pressure Control - Cut Out 30 30
Pressure Control - Diff 30 30
Liquid Line 3/8" O.D. 3/8" O.D.
Suction Line 5/8" O.D. 5/8" O.D.
Air Filter Required One - 20X20X1 Two - 20X20X1
Electrical KRVC - II KRVC - III
Condensing-Unit Type Air Cooled Air Cooled
Horsepower 2HP 3HP
Phase One Three
Volts 208/230 208/230
Hertz 50 or 60 50 or 60
Condenser Full-Load Amps 14.5 16.5
Maximum Fuse Size 30 30
Minimum Circuit Ampacity 19.7 23.7
Compressor Rated Load 13.4 14.3
Compressor Locked Rotor 59.0 74.0
Fan Motor Full-Load Amps 1.1 Ea. 1.1Ea.
Fan Motor Horsepower 1/6 Ea. 1/6 Ea.