External Vapor Condenser - KRVC-II and KRVC-III
Kleen-Rite
Vapor Condensers Plant-Tested by the U.S.E.P.A. New
Clean Air Act Requires Perc Vapor Control Occupies
Less Space Service
Once A Month Vs. Everyday |
![]()
![]() |
||||
| Floor Series | KRVC - II | KRVC - II Transfer | KRVC - III | KRVC - III Transfer |
| Sized for: Dry To Dry Only | One Unit Up to 60# | N/A | One Unit Up to 120# | N/A |
| Sized for: Transfer System | N/A | One - 60# Dryer With One - 60# Washer | N/A | One - 60# to #120 Dryer With One - 60# to #120 Washer |
| Number of Evaporator Tanks | One | Two | One | Two |
| Dryer Evap Tank - Port Dia. | 4" | 4" | 4" | 4" |
| Transfer Evap Tank - Port Dia. | N/A | 6" | N/A | 4" |
| Refrigeration | KRVC - II | KRVC - III | KRVC - II![]() KVRC - III |
| Type of Refrigerant | R-22 | R-22 | |
| Lbs. of Refrigerant | 6 Lbs. | 12.5 Lbs. | |
| Expansion Valve - Std Tank | BFVE-AE | BFVE-BC | |
| Expansion Valve - Tra Tank | GR - 1/2C | GR - 1/2C | |
| Suction Accumulator | KR-P/N 000525 | KR-P/N 000525 | |
| Sight Glass | KR-P/N 000153 | KR-P/N 000153 | |
| Pressure Control - Cut In | 60 | 60 | |
| Pressure Control - Cut Out | 30 | 30 | |
| Pressure Control - Diff | 30 | 30 | |
| Liquid Line | 3/8" O.D. | 3/8" O.D. | |
| Suction Line | 5/8" O.D. | 5/8" O.D. | |
| Air Filter Required | One - 20X20X1 | Two - 20X20X1 | |
| Electrical | KRVC - II | KRVC - III | |
| Condensing-Unit Type | Air Cooled | Air Cooled | |
| Horsepower | 2HP | 3HP | |
| Phase | One | Three | |
| Volts | 208/230 | 208/230 | |
| Hertz | 50 or 60 | 50 or 60 | |
| Condenser Full-Load Amps | 14.5 | 16.5 | |
| Maximum Fuse Size | 30 | 30 | |
| Minimum Circuit Ampacity | 19.7 | 23.7 | |
| Compressor Rated Load | 13.4 | 14.3 | |
| Compressor Locked Rotor | 59.0 | 74.0 | |
| Fan Motor Full-Load Amps | 1.1 Ea. | 1.1Ea. | |
| Fan Motor Horsepower | 1/6 Ea. | 1/6 Ea. |